Denali Plus CTR3 Instructions d'exploitation Page 12

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 15
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 11
Page11 www.DENALIplus.com
Fig. 8
NOTE: CARRIER BRACKETS AND SELF ADHESIVE SEALANT ARE FACTORY INSTALLED.
Step #5 - Electrical Connection
Before proceeding further, verify that the power supply is disconnected. Verify that the
appropriate electrical supply requirements have been met. Refer to the table on page 2 for
appropriate electrical requirements. The cooktop is supplied with a 40-inch long conduit for a
connection to an accessible junction box. The conduit consists of three insulated wires. In 120V
units, there is a hot lead conductor (black insulated tinned copper), one insulated ground
conductor (green insulated tinned copper) and a neutral conductor (white insulated tinned
copper). In 240V units, there are two hot lead conductors (one red, one black insulated tinned
copper) and one insulated ground conductor (green insulated tinned copper).
Attach conductor wires to residence wiring in accordance with national, state and local electric
codes.
Grounding: The entire appliance must be grounded at all
times when the electrical power supply is on. Connect the red to red, black to black
and green to ground. Do not ground the appliance with the neutral house supply
wire. A separate ground must be used.
Vue de la page 11
1 2 ... 7 8 9 10 11 12 13 14 15

Commentaires sur ces manuels

Pas de commentaire